CT-guided needle lung biopsy is possible during apneic oxygenation: a case series

CT-guided needle lung biopsy is possible during apneic oxygenation: a case series

Authors

  • Benedict Kjaergaard Department of Cardiothoracic Surgery, Centre for Cardiovascular Research, and Biomedical Research Laboratory, Aalborg University Hospital, Aalborg; Department of Cardiothoracic Surgery, Aalborg University Hospital, Postbox 365, Hobrovej 18-22, DK-9100 Aalborg
  • Peter R. Zepernick Department of Anaesthesiology and Intensive Care, Centre for Cardiovascular Research, Aalborg University Hospital, Aalborg
  • Annette Bergmann Department of Radiology, Aalborg University Hospital, Aalborg
  • Henrik K. Jensen Department of Respiratory Diseases, Aalborg University Hospital, Aalborg
  • Milka Mladenovic Department of Radiology, Aalborg University Hospital, Aalborg
  • Bodil S. Rasmussen Department of Anaesthesiology and Intensive Care, Centre for Cardiovascular Research, Aalborg University Hospital, Aalborg

Keywords:

CT-guided

Abstract

Background: It can be difficult to perform CT guided biopsy of small pulmonary nodules especially if the position is behind a costa or close to the diaphragm and respiratory movements may hamper the procedure. During apneic oxygenation with a pulmonary standstill these movements can be hindered. Methods: Six patients with decreased lung function and suspicious lung nodules are presented. Under general anesthesia including a muscle relaxant and a cuffed tube in the trachea CT guided biopsy was prepared. Just before the biopsy the ventilation mode was switched to a continuous positive airway pressure of 5–10 cm H2O, maintaining 100% oxygen delivery without ventilation. If the position of the lung nodule was inconvenient for biopsy the pressure was increased to up to 17 cm H2O to expand the lungs to a better biopsy position. After retrieving the biopsy controlled ventilation was re-established and a finishing control CT-scan was performed. Blood gas analyses were performed with few minutes interval. Results: All biopsies were diagnostic. All patients survived the procedure with no major complications, but 3 patients developed pneumothorax. The length of apneic oxygenation was median 10 minutes (8–10 minutes). No major changes in vital parameters were observed, and in all patients the peripheral oxygen saturation was 100% throughout the procedure. The arterial oxygen tension rose to very high values and the lowest pH was 7.18. Conclusions: It is possible to perform lung biopsies in selected patients with decreased lung function during apneic oxygenation in at least 10 minutes in a safe way.

Downloads

Published

06-12-2013

Issue

Section

Case Reports

How to Cite

1.
Kjaergaard B, Zepernick PR, Bergmann A, Jensen HK, Mladenovic M, Rasmussen BS. CT-guided needle lung biopsy is possible during apneic oxygenation: a case series. Multidiscip Respir Med [Internet]. 2013 Dec. 6 [cited 2024 Jul. 4];8(9). Available from: https://mrmjournal.org/index.php/mrm/article/view/585